Show plain JSON{"id": "CVE-2015-7909", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.3, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "LOW"}, "impactScore": 3.4, "exploitabilityScore": 3.9}]}, "published": "2016-01-22T11:59:02.773", "references": [{"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-337-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-337-02", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Deferred", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-119"}]}], "descriptions": [{"lang": "en", "value": "Stack-based buffer overflow in Hospira Communication Engine (CE) before 1.2 in LifeCare PCA Infusion System 5.07, Plum A+ Infusion System 13.40, and Plum A+3 Infusion System 13.40 allows remote attackers to cause a denial of service or possibly have unspecified other impact via traffic on TCP port 5000."}, {"lang": "es", "value": "Desbordamiento de buffer basado en pila en Hospira Communication Engine (CE) en versiones anteriores a 1.2 en LifeCare PCA Infusion System 5.07, Plum A+ Infusion System 13.40 y Plum A+3 Infusion System 13.40 permite a atacantes remotos provocar una denegaci\u00f3n de servicio o posiblemente tener otro impacto no especificado a trav\u00e9s de tr\u00e1fico en el puerto TCP 5000."}], "lastModified": "2025-04-12T10:46:40.837", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hospira:communication_engine:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "08733FD8-81E4-4A0A-94E5-712981AC8D8B", "versionEndIncluding": "1.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hospira:lifecare_pca_infusion_system:5.0.7:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B63642C5-8F09-4E27-8CE9-5CFF427989F1"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}