Show plain JSON{"id": "CVE-2017-14006", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 6.4, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2018-03-20T16:29:00.373", "references": [{"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-037-02", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-287"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-798"}]}], "descriptions": [{"lang": "en", "value": "GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices."}, {"lang": "es", "value": "GE Infinia/Infinia, en versiones 1.0, 1.1, 2.1, 3.0 y 3.1, con sistemas de imagen m\u00e9dica Hawkeye 3,1 en todas las versiones actuales afectadas, estos dispositivos emplean credenciales por defecto o embebidas. La explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda permitir que un atacante remoto omita la autenticaci\u00f3n y obtenga acceso a los dispositivos afectados."}], "lastModified": "2024-11-21T03:11:57.107", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:ge:xeleris:1.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "ED9FC013-22FA-43F0-A7C3-CF1955A1DA57"}, {"criteria": "cpe:2.3:a:ge:xeleris:1.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CE6522AA-1060-4014-9249-EB5F7F6EBCE4"}, {"criteria": "cpe:2.3:a:ge:xeleris:2.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E31D0274-3664-41AC-B300-BA9071D07D7C"}, {"criteria": "cpe:2.3:a:ge:xeleris:3.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D430803D-4C3B-4D37-881B-963F3E7CCACC"}, {"criteria": "cpe:2.3:a:ge:xeleris:3.1:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "7D5DCB64-AD1D-47BC-B343-3B7C2E61BDB4"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}