Show plain JSON{"id": "CVE-2019-13549", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2019-10-25T18:15:10.880", "references": [{"url": "http://seclists.org/fulldisclosure/2019/Oct/46", "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "http://seclists.org/fulldisclosure/2019/Oct/46", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-306"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-306"}]}], "descriptions": [{"lang": "en", "value": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication."}, {"lang": "es", "value": "El Interfaz web Rittal Chiller SK 3232-Series seg\u00fan el firmware Carel pCOWeb A1.5.3 - B1.2.4. El mecanismo de autenticaci\u00f3n en los sistemas afectados no proporciona un nivel suficiente de protecci\u00f3n contra cambios de configuraci\u00f3n no autorizados. Las operaciones primarias, a saber, encender y apagar la unidad de enfriamiento y establecer el punto de ajuste de temperatura, se pueden modificar sin autenticaci\u00f3n."}], "lastModified": "2024-11-21T04:25:07.587", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:carel:pcoweb_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6B7B4C31-67E0-488A-9297-B8E8E158DC3E", "versionEndIncluding": "b1.2.4", "versionStartIncluding": "a1.5.3"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:rittal:chiller_sk_3232:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3FAC3FD5-429B-48BF-B519-47CAD3E718C0"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}