Show plain JSON{"id": "CVE-2019-3989", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 9.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "MEDIUM", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 9.8, "attackVector": "NETWORK", "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 3.9}]}, "published": "2019-12-11T23:15:11.557", "references": [{"url": "https://www.tenable.com/security/research/tra-2019-51", "tags": ["Exploit", "Third Party Advisory"], "source": "vulnreport@tenable.com"}, {"url": "https://www.tenable.com/security/research/tra-2019-51", "tags": ["Exploit", "Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-78"}]}], "descriptions": [{"lang": "en", "value": "Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due to improperly sanitized input when retrieving internal network configuration data."}, {"lang": "es", "value": "El firmware de Blink XT2 Sync Module versiones anteriores a 2.13.11, permite a atacantes remotos ejecutar comandos arbitrarios en el dispositivo debido a una entrada saneada inapropiadamente cuando se recuperan los datos de configuraci\u00f3n de la red interna."}], "lastModified": "2024-11-21T04:43:00.877", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:amazon:blink_xt2_sync_module_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FFEE7C5F-CA30-4B2D-A0EE-B7425144489E", "versionEndExcluding": "2.13.11"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:amazon:blink_xt2_sync_module:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5AFBC607-8887-4CC7-99D0-60D9C8993EE9"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "vulnreport@tenable.com"}