Show plain JSON{"id": "CVE-2020-12037", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2020-06-29T14:15:11.537", "references": [{"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01", "tags": ["Not Applicable"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-170-02", "tags": ["Third Party Advisory"], "source": "nvd@nist.gov"}, {"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01", "tags": ["Not Applicable"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-259"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-319"}]}], "descriptions": [{"lang": "en", "value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device."}, {"lang": "es", "value": "Baxter PrismaFlex todas las versiones, PrisMax todas las versiones anteriores a 3.x, los dispositivos afectados no implementan cifrado de datos en tr\u00e1nsito (por ejemplo, TLS/SSL) cuando se configuran para enviar datos de tratamiento a un PDMS (Patient Data Management System) o un sistema EMR (Electronic Medical Record). Un atacante podr\u00eda observar datos confidenciales enviados desde el dispositivo"}], "lastModified": "2024-11-21T04:59:09.630", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:baxter:prismaflex_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B8874804-02E2-4E74-94C6-F103DCDC854E"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:baxter:prismaflex:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8E5DB2B2-5D9E-494B-A860-FE2F4BC4C767"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:baxter:prismax_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8F197DAD-63A3-4598-BBFC-0014707B3A01", "versionEndExcluding": "3.0"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:baxter:prismax:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "A5EB1A30-A514-437D-B976-451CF003955D"}], "operator": "OR"}], "operator": "AND"}], "evaluatorComment": "At the time of analysis, information provided did not align with the data (including CVE number) in the advisory.", "sourceIdentifier": "ics-cert@hq.dhs.gov"}