Show plain JSON{"id": "CVE-2020-7588", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.3, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 1.4, "exploitabilityScore": 3.9}]}, "published": "2020-07-14T14:15:18.993", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-20"}]}, {"type": "Secondary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-20"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de un paquete especialmente dise\u00f1ado al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara"}], "lastModified": "2024-11-21T05:37:25.660", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2"}, {"criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2"}, {"criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2"}, {"criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768"}, {"criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3"}, {"criteria": "cpe:2.3:a:siemens:opcenter_rd\\&l:8.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E"}, {"criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "524AE90C-821A-4864-B3B2-33C083B536CB"}, {"criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E6324685-60ED-44CC-BAEA-3BEEBE681AC5"}, {"criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "vulnerable": true, "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA"}, {"criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA"}, {"criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2190AEE1-7EEA-48A9-B6C7-FF4B3A26008E", "versionEndIncluding": "15.1", "versionStartIncluding": "15"}, {"criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C"}, {"criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update_1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4E011D6F-CC5F-4278-80AB-D568730AA041"}, {"criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D"}, {"criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}