Show plain JSON{"id": "CVE-2021-25128", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 7.2, "accessVector": "LOCAL", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "acInsufInfo": false, "impactScore": 10.0, "baseSeverity": "HIGH", "obtainAllPrivilege": false, "exploitabilityScore": 3.9, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}]}, "published": "2021-01-29T19:15:13.697", "references": [{"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf04073en_us", "tags": ["Vendor Advisory"], "source": "security-alert@hpe.com"}, {"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbhf04073en_us", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-22"}]}], "descriptions": [{"lang": "en", "value": "The Baseboard Management Controller(BMC) in HPE Cloudline CL5800 Gen9 Server; HPE Cloudline CL5200 Gen9 Server; HPE Cloudline CL4100 Gen10 Server; HPE Cloudline CL3100 Gen10 Server; HPE Cloudline CL5800 Gen10 Server BMC firmware has a local spx_restservice gethelpdata_func function path traversal vulnerability."}, {"lang": "es", "value": "El Baseboard Management Controller (BMC) en HPE Cloudline CL5800 Gen9 Server; HPE Cloudline CL5200 Gen9 Server; HPE Cloudline CL4100 Gen10 Server; HPE Cloudline CL3100 Gen10 Server, el firmware HPE Cloudline CL5800 Gen10 Server BMC, presenta una vulnerabilidad de salto de ruta local en la funci\u00f3n gethelpdata_func de spx_restservice"}], "lastModified": "2024-11-21T05:54:24.470", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hpe:cloudline_cl3100_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "662D4441-34A1-4BBF-9EB4-1FC94D1736F1"}, {"criteria": "cpe:2.3:o:hpe:cloudline_cl3100_gen10_server_firmware:1.10.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "9D130324-445C-47F1-993E-387399A9AEB6"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hpe:cloudline_cl3100_gen10_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BCB48BA1-2048-42F4-A195-F910B875196B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hpe:cloudline_cl4100_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "81ACE979-5E08-40CC-A33B-F602FE14CCE4"}, {"criteria": "cpe:2.3:o:hpe:cloudline_cl4100_gen10_server_firmware:1.10.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6C211F7F-A1E9-4851-A26F-B83B57C32133"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hpe:cloudline_cl4100_gen10_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5FD84248-F258-4F3A-BD05-E474FE7D6697"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hpe:cloudline_cl5200_gen9_server_firmware:1.07.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "190FEC40-B9DA-48D6-8DB2-9D524A8FD088"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hpe:cloudline_cl5200_gen9_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "D8BB0745-54DA-4792-B570-AE037E7C38D5"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hpe:cloudline_cl5800_gen10_server_firmware:1.08.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E0D91102-123F-4009-AB13-BE897220BACE"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hpe:cloudline_cl5800_gen10_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5410F9D6-9040-4155-A499-30B1814BF36B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:hpe:cloudline_cl5800_gen9_server_firmware:1.09.0.0:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4C359672-5A70-4D99-972D-9A84A518B8AB"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:hpe:cloudline_cl5800_gen9_server:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "149886B8-4820-4D7F-ACA6-68FE3DE32D18"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "security-alert@hpe.com"}