Show plain JSON{"id": "CVE-2021-37177", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 3.3, "accessVector": "ADJACENT_NETWORK", "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "LOW", "obtainAllPrivilege": false, "exploitabilityScore": 6.5, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.5, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 2.8}, {"type": "Secondary", "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.5, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 2.8}]}, "published": "2021-09-14T11:15:25.540", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-471"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The status provided by the syslog clients managed by the affected software can be manipulated by an unauthenticated attacker in the same network of the affected system."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V3.0 SP2). El estado proporcionado por los clientes syslog administrados por el software afectado puede ser manipulado por un atacante no autenticado en la misma red del sistema afectado"}], "lastModified": "2025-04-23T20:15:29.400", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F65F9901-F4BD-4484-9749-D5022245D686", "versionEndExcluding": "3.0"}, {"criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:-:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4F03BAD5-7B90-4212-ACBC-3C878C02CDAA"}, {"criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.0:sp1:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "E5BACE03-50A7-4279-8CA5-2BB95224D485"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}