Show plain JSON{"id": "CVE-2022-24319", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 4.3, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.9, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 2.2}]}, "published": "2022-02-09T23:15:20.087", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05", "tags": ["Patch", "Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md", "tags": ["Third Party Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2022/MNDT-2022-0018/MNDT-2022-0018.md", "tags": ["Third Party Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-295"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-295"}]}], "descriptions": [{"lang": "en", "value": "A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"}, {"lang": "es", "value": "Una CWE-295: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Certificados inapropiada que podr\u00eda permitir un ataque de tipo Man-in-theMiddle cuando son interceptadas las comunicaciones entre el cliente y el servidor web de Geo SCADA. Producto afectado: ClearSCADA (todas las versiones), EcoStruxure Geo SCADA Expert 2019 (todas las versiones), EcoStruxure Geo SCADA Expert 2020 (todas las versiones)"}], "lastModified": "2024-11-21T06:50:09.737", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:clearscada:-:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "A0BBB84D-01D2-445E-8827-A899A0A2107A"}, {"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "665F4C4F-CC00-4484-B6FD-5E77EDBCD242"}, {"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BA51B4B8-FF75-4BAE-A62B-E4B618CC7B10"}], "operator": "OR"}]}], "sourceIdentifier": "cybersecurity@se.com"}