Show plain JSON{"id": "CVE-2022-24321", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2022-02-09T23:15:20.180", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05", "tags": ["Patch", "Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-05", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-754"}]}], "descriptions": [{"lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"}, {"lang": "es", "value": "Una CWE-754: Se presenta una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales que podr\u00eda causar una denegaci\u00f3n de servicio contra el servidor Geo SCADA cuando se recibe una petici\u00f3n HTTP malformada. Producto afectado: ClearSCADA (todas las versiones), EcoStruxure Geo SCADA Expert 2019 (todas las versiones), EcoStruxure Geo SCADA Expert 2020 (todas las versiones)"}], "lastModified": "2024-11-21T06:50:09.953", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:clearscada:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8117E9AF-97C7-4C10-BE59-5341D32667F4"}, {"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "665F4C4F-CC00-4484-B6FD-5E77EDBCD242"}, {"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BA51B4B8-FF75-4BAE-A62B-E4B618CC7B10"}], "operator": "OR"}]}], "sourceIdentifier": "cybersecurity@se.com"}