Show plain JSON{"id": "CVE-2022-39157", "metrics": {"cvssMetricV31": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}]}, "published": "2022-11-08T11:15:11.330", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf", "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf", "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-125"}]}, {"type": "Secondary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-125"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)"}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid V34.0 (Todas las versiones < V34.0.252), Parasolid V34.0 (Todas las versiones >= V34.0.252 < V34.0.254), Parasolid V34.1 (Todas las versiones < V34 .1.242), Parasolid V34.1 (Todas las versiones >= V34.1.242 < V34.1.244), Parasolid V35.0 (Todas las versiones < V35.0.170), Parasolid V35.0 (Todas las versiones >= V35. 0.170 < V35.0.184), Simcenter Femap (todas las versiones < V2023.1). La aplicaci\u00f3n afectada contiene una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-17745)"}], "lastModified": "2024-11-21T07:17:41.317", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "4B458F81-37C3-4C1D-9626-6C12BF48AC11", "versionEndExcluding": "34.0.254", "versionStartIncluding": "34.0.252"}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "19C0AC71-D36A-46D5-96C2-384821AE2044", "versionEndExcluding": "34.1.244", "versionStartIncluding": "34.1.242"}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B432DF2D-5706-4C37-906C-30299CD13BF3", "versionEndExcluding": "35.0.184", "versionStartIncluding": "35.0.170"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}