CVE-2024-22040

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service.
Configurations

No configuration.

History

21 Nov 2024, 08:55

Type Values Removed Values Added
References () https://cert-portal.siemens.com/productcert/html/ssa-225840.html - () https://cert-portal.siemens.com/productcert/html/ssa-225840.html -
References () https://cert-portal.siemens.com/productcert/html/ssa-953710.html - () https://cert-portal.siemens.com/productcert/html/ssa-953710.html -

14 May 2024, 16:16

Type Values Removed Values Added
References
  • () https://cert-portal.siemens.com/productcert/html/ssa-953710.html -
Summary
  • (es) Se ha identificado una vulnerabilidad en Cerberus PRO EN Engineering Tool (todas las versiones), Cerberus PRO EN Fire Panel FC72x (todas las versiones &lt; IP8 SR4), Cerberus PRO EN X200 Cloud Distribution (todas las versiones &lt; V4.3.5618), Cerberus PRO EN X300 Cloud Distribución (todas las versiones &lt; V4.3.5617), Sinteso FS20 EN Engineering Tool (todas las versiones), Sinteso FS20 EN Fire Panel FC20 (todas las versiones &lt; MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution (todas las versiones &lt; V4.3.5618), Sinteso Distribución en la nube FS20 EN X300 (todas las versiones
Summary (en) A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution (All versions < V4.3.5617), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service. (en) A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service.

12 Mar 2024, 11:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-12 11:15

Updated : 2024-11-21 08:55


NVD link : CVE-2024-22040

Mitre link : CVE-2024-22040

CVE.ORG link : CVE-2024-22040


JSON object : View

Products Affected

No product.

CWE
CWE-125

Out-of-bounds Read