CVE-2024-3010

A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.258296 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.258296 Third Party Advisory VDB Entry
https://vuldb.com/?submit.301489 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.258296 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.258296 Third Party Advisory VDB Entry
https://vuldb.com/?submit.301489 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\(775\):*:*:*:*:*:*:*
cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*

History

15 Jan 2025, 18:24

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.258296 - () https://vuldb.com/?ctiid.258296 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.258296 - () https://vuldb.com/?id.258296 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.301489 - () https://vuldb.com/?submit.301489 - Third Party Advisory, VDB Entry
CWE CWE-787
CPE cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\(775\):*:*:*:*:*:*:*
First Time Tenda
Tenda fh1205 Firmware
Tenda fh1205

21 Nov 2024, 09:28

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/FH/FH1205/formSetCfm.md -
References () https://vuldb.com/?ctiid.258296 - () https://vuldb.com/?ctiid.258296 -
References () https://vuldb.com/?id.258296 - () https://vuldb.com/?id.258296 -
References () https://vuldb.com/?submit.301489 - () https://vuldb.com/?submit.301489 -

11 Apr 2024, 01:25

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad fue encontrada en Tenda FH1205 2.0.0.7(775) y clasificada como crítica. La función formSetCfm del archivo /goform/setcfm es afectada por esta vulnerabilidad. La manipulación del argumento funcpara1 provoca un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-258296. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

28 Mar 2024, 00:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-28 00:15

Updated : 2025-01-15 18:24


NVD link : CVE-2024-3010

Mitre link : CVE-2024-3010

CVE.ORG link : CVE-2024-3010


JSON object : View

Products Affected

tenda

  • fh1205
  • fh1205_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write