Show plain JSON{"id": "CVE-2024-47964", "cveTags": [], "metrics": {"cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}], "cvssMetricV40": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "cvssData": {"safety": "NOT_DEFINED", "version": "4.0", "recovery": "NOT_DEFINED", "baseScore": 8.4, "automatable": "NOT_DEFINED", "attackVector": "LOCAL", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "userInteraction": "ACTIVE", "attackComplexity": "LOW", "attackRequirements": "NONE", "privilegesRequired": "NONE", "modifiedAttackVector": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subsequentSystemIntegrity": "NONE", "vulnerableSystemIntegrity": "HIGH", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "confidentialityRequirements": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "vulnerableSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "NONE", "vulnerableSystemConfidentiality": "HIGH", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED"}}]}, "published": "2024-10-10T18:15:08.470", "references": [{"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-21", "tags": ["Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-787"}]}, {"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-122"}]}], "descriptions": [{"lang": "en", "value": "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can manipulate users to visit a malicious page or file to leverage this vulnerability to execute code in the context of the current process."}, {"lang": "es", "value": "Delta Electronics CNCSoft-G2 carece de una validaci\u00f3n adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un b\u00fafer basado en pila de longitud fija. Un atacante puede manipular a los usuarios para que visiten una p\u00e1gina o un archivo malicioso y aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual."}], "lastModified": "2024-10-17T14:37:25.183", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:deltaww:cncsoft-g2:2.1.0.10:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "106DB50E-21E4-48E9-BC69-B789B917EF6E"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}