CVE-2025-0167

When asked to use a `.netrc` file for credentials **and** to follow HTTP redirects, curl could leak the password used for the first host to the followed-to host under certain circumstances. This flaw only manifests itself if the netrc file has a `default` entry that omits both login and password. A rare circumstance.
References
Configurations

Configuration 1 (hide)

cpe:2.3:a:haxx:curl:*:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:a:netapp:element_software:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap:9:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap_tools:9:*:*:*:*:vmware_vsphere:*:*
cpe:2.3:a:netapp:solidfire_\&_hci_management_node:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:solidfire_\&_hci_storage_node:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*

History

30 Jul 2025, 19:41

Type Values Removed Values Added
CPE cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:element_software:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap_tools:9:*:*:*:*:vmware_vsphere:*:*
cpe:2.3:a:netapp:solidfire_\&_hci_management_node:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:a:haxx:curl:*:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:solidfire_\&_hci_storage_node:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap:9:*:*:*:*:*:*:*
cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*
cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
CWE NVD-CWE-noinfo
First Time Netapp h410s Firmware
Netapp h300s
Netapp h500s Firmware
Netapp h700s Firmware
Netapp h610c Firmware
Netapp h700s
Netapp h410c Firmware
Netapp h610c
Netapp h615c Firmware
Haxx curl
Netapp element Software
Netapp ontap Select Deploy Administration Utility
Netapp solidfire \& Hci Management Node
Netapp h410s
Netapp bootstrap Os
Netapp h410c
Netapp solidfire \& Hci Storage Node
Netapp h615c
Netapp h610s Firmware
Haxx
Netapp h300s Firmware
Netapp h500s
Netapp hci Compute Node
Netapp ontap
Netapp
Netapp h610s
Netapp ontap Tools
References () https://curl.se/docs/CVE-2025-0167.html - () https://curl.se/docs/CVE-2025-0167.html - Vendor Advisory
References () https://curl.se/docs/CVE-2025-0167.json - () https://curl.se/docs/CVE-2025-0167.json - Vendor Advisory
References () https://hackerone.com/reports/2917232 - () https://hackerone.com/reports/2917232 - Exploit, Issue Tracking, Third Party Advisory
References () https://security.netapp.com/advisory/ntap-20250306-0008/ - () https://security.netapp.com/advisory/ntap-20250306-0008/ - Third Party Advisory

07 Mar 2025, 01:15

Type Values Removed Values Added
References
  • () https://security.netapp.com/advisory/ntap-20250306-0008/ -

06 Feb 2025, 15:15

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 3.4
References () https://curl.se/docs/CVE-2025-0167.html - () https://curl.se/docs/CVE-2025-0167.html -
Summary
  • (es) Cuando se le pide que use un archivo `.netrc` para las credenciales **y** para seguir redirecciones HTTP, curl podría filtrar la contraseña utilizada para el primer host al host siguiente en determinadas circunstancias. Esta falla solo se manifiesta si el archivo netrc tiene una entrada `default` que omite tanto el nombre de usuario como la contraseña. Una circunstancia poco común.

05 Feb 2025, 10:15

Type Values Removed Values Added
New CVE

Information

Published : 2025-02-05 10:15

Updated : 2025-07-30 19:41


NVD link : CVE-2025-0167

Mitre link : CVE-2025-0167

CVE.ORG link : CVE-2025-0167


JSON object : View

Products Affected

netapp

  • ontap_tools
  • solidfire_\&_hci_management_node
  • element_software
  • ontap_select_deploy_administration_utility
  • ontap
  • h410c_firmware
  • h700s_firmware
  • solidfire_\&_hci_storage_node
  • h300s
  • h610s
  • h615c
  • h610s_firmware
  • h410s
  • h410s_firmware
  • h610c_firmware
  • h700s
  • h500s
  • h500s_firmware
  • h615c_firmware
  • h410c
  • h610c
  • hci_compute_node
  • h300s_firmware
  • bootstrap_os

haxx

  • curl