Vulnerabilities (CVE)

Filtered by CWE-120
Total 3106 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-46549 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo.
CVE-2022-46548 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient.
CVE-2022-46547 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer.
CVE-2022-46546 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic.
CVE-2022-46545 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting.
CVE-2022-46544 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand.
CVE-2022-46543 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat.
CVE-2022-46542 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat.
CVE-2022-46535 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/SetClientState.
CVE-2022-46534 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the speed_dir parameter at /goform/SetSpeedWan.
CVE-2022-46533 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeed parameter at /goform/SetClientState.
CVE-2022-46530 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mac parameter at /goform/GetParentControlInfo.
CVE-2022-46532 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceMac parameter at /goform/addWifiMacFilter.
CVE-2022-46531 1 Tenda 2 F1203, F1203 Firmware 2025-04-16 N/A 7.5 HIGH
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/addWifiMacFilter.
CVE-2024-46601 1 Elspec-ltd 2 G5dfr, G5dfr Firmware 2025-04-16 N/A 7.5 HIGH
Elspec Engineering G5 Digital Fault Recorder Firmware v1.2.1.12 was discovered to contain a buffer overflow.
CVE-2025-29480 1 Osgeo 1 Gdal 2025-04-15 N/A 5.5 MEDIUM
Buffer Overflow vulnerability in gdal 3.10.2 allows a local attacker to cause a denial of service via the OGRSpatialReference::Release function.
CVE-2025-29482 1 Struktur 1 Libheif 2025-04-15 N/A 6.2 MEDIUM
Buffer Overflow vulnerability in libheif 1.19.7 allows a local attacker to execute arbitrary code via the SAO (Sample Adaptive Offset) processing of libde265.
CVE-2025-29481 1 Libbpf Project 1 Libbpf 2025-04-15 N/A 6.2 MEDIUM
Buffer Overflow vulnerability in libbpf 1.5.0 allows a local attacker to execute arbitrary code via the bpf_object__init_prog` function of libbpf.
CVE-2022-45712 1 Ip-com 2 M50, M50 Firmware 2025-04-15 N/A 9.8 CRITICAL
IP-COM M50 V15.11.0.33(10768) was discovered to contain a buffer overflow via the rules parameter in the formAddDnsForward function.
CVE-2022-45710 1 Ip-com 2 M50, M50 Firmware 2025-04-15 N/A 9.8 CRITICAL
IP-COM M50 V15.11.0.33(10768) was discovered to contain multiple buffer overflows via the pEnable, pLevel, and pModule parameters in the formSetDebugCfg function.