Total
1739 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-32310 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | N/A | 8.0 HIGH |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. | |||||
CVE-2024-32312 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | N/A | 5.7 MEDIUM |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. | |||||
CVE-2024-32311 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | |||||
CVE-2024-32299 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | |||||
CVE-2024-32316 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. | |||||
CVE-2024-32318 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function. | |||||
CVE-2024-32320 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 5.9 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | |||||
CVE-2024-33215 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat. | |||||
CVE-2024-33212 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm. | |||||
CVE-2024-33211 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.3 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter in ip/goform/QuickIndex. | |||||
CVE-2024-33213 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic. | |||||
CVE-2024-33217 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter in ip/goform/addressNat. | |||||
CVE-2024-35580 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formSetIptv. | |||||
CVE-2024-35579 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 7.7 HIGH |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formSetIptv. | |||||
CVE-2024-35578 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 8.0 HIGH |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv. | |||||
CVE-2024-35576 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 5.2 MEDIUM |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formSetIptv. | |||||
CVE-2024-32317 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | |||||
CVE-2024-32306 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2025-03-17 | N/A | 5.7 MEDIUM |
Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. | |||||
CVE-2024-30612 | 1 Tenda | 2 Ac10u, Ac10u Firmware | 2025-03-17 | N/A | 8.1 HIGH |
Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function. | |||||
CVE-2024-30628 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-14 | N/A | 9.8 CRITICAL |
Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function. |