CVE-2022-25782 1 Secomea 8 Gatemanager 4250, Gatemanager 4250 Firmware, Gatemanager 4260 and 5 more 2024-11-21 5.5 MEDIUM 5.4 MEDIUM
Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7.
CVE-2022-25636 4 Debian, Linux, Netapp and 1 more 13 Debian Linux, Linux Kernel, H300e and 10 more 2024-11-21 6.9 MEDIUM 7.8 HIGH
net/netfilter/nf_dup_netdev.c in the Linux kernel 5.4 through 5.6.10 allows local users to gain privileges because of a heap out-of-bounds write. This is related to nf_tables_offload.
CVE-2022-25372 2 Microsoft, Pritunl 2 Windows, Pritunl-client-electron 2024-11-21 7.2 HIGH 7.8 HIGH
Pritunl Client through 1.2.3019.52 on Windows allows local privilege escalation, related to an ACL entry for CREATOR OWNER in platform_windows.go.
CVE-2022-25311 1 Siemens 2 Sinec Network Management System, Sinema Server 2024-11-21 6.5 MEDIUM 7.3 HIGH
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.
CVE-2022-25150 1 Malwarebytes 1 Binisoft Windows Firewall Control 2024-11-21 4.6 MEDIUM 7.8 HIGH
In Malwarebytes Binisoft Windows Firewall Control before 6.8.1.0, programs executed from the Tools tab can be used to escalate privileges.
CVE-2022-25089 1 Kofax 1 Printix 2024-11-21 7.5 HIGH 9.8 CRITICAL
Printix Secure Cloud Print Management through 1.3.1106.0 incorrectly uses Privileged APIs to modify values in HKEY_LOCAL_MACHINE via UITasks.PersistentRegistryData.
CVE-2022-24927 1 Samsung 1 Video Player 2024-11-21 7.5 HIGH 4.2 MEDIUM
Improper privilege management vulnerability in Samsung Video Player prior to version 7.3.15.30 allows attackers to execute video files without permission.
CVE-2022-24812 1 Grafana 1 Grafana 2024-11-21 6.0 MEDIUM 8.0 HIGH
Grafana is an open-source platform for monitoring and observability. When fine-grained access control is enabled and a client uses Grafana API Key to make requests, the permissions for that API Key are cached for 30 seconds for the given organization. Because of the way the cache ID is constructed, the consequent requests with any API Key evaluate to the same permissions as the previous requests. This can lead to an escalation of privileges, when for example a first request is made with Admin permissions, and the second request with different API Key is made with Viewer permissions, the second request will get the cached permissions from the previous Admin, essentially accessing higher privilege than it should. The vulnerability is only impacting Grafana Enterprise when the fine-grained access control beta feature is enabled and there are more than one API Keys in one organization with different roles assigned. All installations after Grafana Enterprise v8.1.0-beta1 should be upgraded as soon as possible. As an alternative, disable fine-grained access control will mitigate the vulnerability.
CVE-2022-24750 1 Uvnc 1 Ultravnc 2024-11-21 7.2 HIGH 8.8 HIGH
UltraVNC is a free and open source remote pc access software. A vulnerability has been found in versions prior to 1.3.8.0 in which the DSM plugin module, which allows a local authenticated user to achieve local privilege escalation (LPE) on a vulnerable system. The vulnerability has been fixed to allow loading of plugins from the installed directory. Affected users should upgrade their UltraVNC to 1.3.8.1. Users unable to upgrade should not install and run UltraVNC server as a service. It is advisable to create a scheduled task on a low privilege account to launch WinVNC.exe instead. There are no known workarounds if winvnc needs to be started as a service.
CVE-2022-24637 1 Openwebanalytics 1 Open Web Analytics 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
Open Web Analytics (OWA) before 1.7.4 allows an unauthenticated remote attacker to obtain sensitive user information, which can be used to gain admin privileges by leveraging cache hashes. This occurs because files generated with '<?php (instead of the intended "<?php sequence) aren't handled by the PHP interpreter.
CVE-2022-24408 1 Siemens 4 Sinumerik Mc, Sinumerik Mc Firmware, Sinumerik One and 1 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.
CVE-2022-23921 1 Ge 1 Proficy Cimplicitiy 2024-11-21 3.7 LOW 7.5 HIGH
Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already running a project, and the server is licensed for multiple projects.
CVE-2022-23743 1 Checkpoint 1 Zonealarm 2024-11-21 7.2 HIGH 7.8 HIGH
Check Point ZoneAlarm before version 15.8.200.19118 allows a local actor to escalate privileges during the upgrade process. In addition, weak permissions in the ProgramData\CheckPoint\ZoneAlarm\Data\Updates directory allow a local attacker the ability to execute an arbitrary file write, leading to execution of code as local system, in ZoneAlarm versions before v15.8.211.192119
CVE-2022-23720 1 Pingidentity 1 Pingid Integration For Windows Login 2024-11-21 4.4 MEDIUM 7.5 HIGH
PingID Windows Login prior to 2.8 does not alert or halt operation if it has been provisioned with the full permissions PingID properties file. An IT administrator could mistakenly deploy administrator privileged PingID API credentials, such as those typically used by PingFederate, into PingID Windows Login user endpoints. Using sensitive full permissions properties file outside of a privileged trust boundary leads to an increased risk of exposure or discovery, and an attacker could leverage these credentials to perform administrative actions against PingID APIs or endpoints.
CVE-2022-23485 1 Sentry 1 Sentry 2024-11-21 N/A 6.4 MEDIUM
Sentry is an error tracking and performance monitoring platform. In versions of the sentry python library prior to 22.11.0 an attacker with a known valid invite link could manipulate a cookie to allow the same invite link to be reused on multiple accounts when joining an organization. As a result an attacker with a valid invite link can create multiple users and join an organization they may not have been originally invited to. This issue was patched in version 22.11.0. Sentry SaaS customers do not need to take action. Self-hosted Sentry installs on systems which can not upgrade can disable the invite functionality until they are ready to deploy the patched version by editing their `sentry.conf.py` file (usually located at `~/.sentry/`).
CVE-2022-23296 1 Microsoft 10 Windows 10, Windows 11, Windows 7 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
Windows Installer Elevation of Privilege Vulnerability
CVE-2022-23160 1 Dell 1 Emc Powerscale Onefs 2024-11-21 4.0 MEDIUM 5.4 MEDIUM
Dell PowerScale OneFS, versions 8.2.0-9.3.0, contains an Improper Handling of Insufficient Permissions vulnerability. An remote malicious user could potentially exploit this vulnerability, leading to gaining write permissions on read-only files.
CVE-2022-22509 1 Phoenixcontact 130 Fl Switch 2005, Fl Switch 2005 Firmware, Fl Switch 2008 and 127 more 2024-11-21 9.0 HIGH 8.8 HIGH
In Phoenix Contact FL SWITCH Series 2xxx in version 3.00 an incorrect privilege assignment allows an low privileged user to enable full access to the device configuration.
CVE-2022-22483 5 Hp, Ibm, Linux and 2 more 6 Hp-ux, Aix, Db2 and 3 more 2024-11-21 N/A 6.5 MEDIUM
IBM Db2 for Linux, UNIX and Windows 9.7, 10.1, 10.5, 11.1, and 11.5 is vulnerable to an information disclosure in some scenarios due to unauthorized access caused by improper privilege management when CREATE OR REPLACE command is used. IBM X-Force ID: 225979.
CVE-2022-22390 4 Ibm, Linux, Microsoft and 1 more 4 Db2, Linux Kernel, Windows and 1 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
IBM Db2 for Linux, UNIX and Windows 9.7, 10.1, 10.5, 11.1, and 11.5 may be vulnerable to an information disclosure caused by improper privilege management when table function is used. IBM X-Force ID: 221973.