Total
4244 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2023-30253 | 1 Dolibarr | 1 Dolibarr Erp\/crm | 2025-01-14 | N/A | 8.8 HIGH |
Dolibarr before 17.0.1 allows remote code execution by an authenticated user via an uppercase manipulation: <?PHP instead of <?php in injected data. | |||||
CVE-2022-2488 | 1 Wavlink | 4 Wl-wn535k2, Wl-wn535k2 Firmware, Wl-wn535k3 and 1 more | 2025-01-14 | N/A | 8.0 HIGH |
A vulnerability was found in WAVLINK WN535K2 and WN535K3 and classified as critical. This issue affects some unknown processing of the file /cgi-bin/touchlist_sync.cgi. The manipulation of the argument IP leads to os command injection. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-12686 | 1 Beyondtrust | 2 Privileged Remote Access, Remote Support | 2025-01-14 | N/A | 6.6 MEDIUM |
A vulnerability has been discovered in Privileged Remote Access (PRA) and Remote Support (RS) which can allow an attacker with existing administrative privileges to inject commands and run as a site user. | |||||
CVE-2025-20055 | 2025-01-14 | N/A | 9.8 CRITICAL | ||
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340 provided by Y'S corporation. An attacker who can access the affected product may execute an arbitrary OS command. | |||||
CVE-2025-20016 | 2025-01-14 | N/A | 7.2 HIGH | ||
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340/D440 provided by Y'S corporation. A user with an administrative privilege who logged in to the web management page of the affected product may execute an arbitrary OS command. | |||||
CVE-2024-28015 | 2025-01-14 | N/A | 9.8 CRITICAL | ||
Improper Neutralization of Special Elements used in an OS Command vulnerability in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command with the root privilege via the internet. | |||||
CVE-2023-34152 | 3 Fedoraproject, Imagemagick, Redhat | 4 Extra Packages For Enterprise Linux, Fedora, Imagemagick and 1 more | 2025-01-13 | N/A | 9.8 CRITICAL |
A vulnerability was found in ImageMagick. This security flaw cause a remote code execution vulnerability in OpenBlob with --enable-pipes configured. | |||||
CVE-2024-29185 | 1 Freescout | 1 Freescout | 2025-01-10 | N/A | 9.0 CRITICAL |
FreeScout is a self-hosted help desk and shared mailbox. Versions prior to 1.8.128 are vulnerable to OS Command Injection in the /public/tools.php source file. The value of the php_path parameter is being executed as an OS command by the shell_exec function, without validating it. This allows an adversary to execute malicious OS commands on the server. A practical demonstration of the successful command injection attack extracted the /etc/passwd file of the server. This represented the complete compromise of the server hosting the FreeScout application. This attack requires an attacker to know the `App_Key` of the application. This limitation makes the Attack Complexity to be High. If an attacker gets hold of the `App_Key`, the attacker can compromise the Complete server on which the application is deployed. Version 1.8.128 contains a patch for this issue. | |||||
CVE-2022-37056 | 1 Dlink | 2 Go-rt-ac750, Go-rt-ac750 Firmware | 2025-01-09 | N/A | 9.8 CRITICAL |
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 and GO-RT-AC750_revB_FWv200b02 is vulnerable to Command Injection via /cgibin, hnap_main, | |||||
CVE-2019-10891 | 1 Dlink | 2 Dir-806, Dir-806 Firmware | 2025-01-09 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered in D-Link DIR-806 devices. There is a command injection in function hnap_main, which calls system() without checking the parameter that can be controlled by user, and finally allows remote attackers to execute arbitrary shell commands with a special HTTP header. | |||||
CVE-2024-8809 | 1 Cohesive | 1 Vns3 | 2025-01-09 | N/A | 8.8 HIGH |
Cohesive Networks VNS3 Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Cohesive Networks VNS3. Authentication is required to exploit this vulnerability. The specific flaw exists within the web service, which listens on TCP port 8000 by default. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-24178. | |||||
CVE-2024-43657 | 2025-01-09 | N/A | 8.8 HIGH | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
CVE-2024-43656 | 2025-01-09 | N/A | 8.8 HIGH | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
CVE-2024-43654 | 2025-01-09 | N/A | 8.8 HIGH | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
CVE-2024-43653 | 2025-01-09 | N/A | 8.8 HIGH | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
CVE-2024-43652 | 2025-01-09 | N/A | 8.8 HIGH | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | |||||
CVE-2024-43649 | 2025-01-09 | N/A | 8.8 HIGH | ||
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | |||||
CVE-2024-43648 | 2025-01-09 | N/A | 8.8 HIGH | ||
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | |||||
CVE-2024-43655 | 2025-01-09 | N/A | N/A | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
CVE-2024-43651 | 2025-01-09 | N/A | N/A | ||
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |