Vulnerabilities (CVE)

Filtered by CWE-787
Total 12292 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-38227 1 Xpdf Project 1 Xpdf 2024-11-21 N/A 7.8 HIGH
XPDF commit ffaf11c was discovered to contain a stack overflow via __asan_memcpy at asan_interceptors_memintrinsics.cpp.
CVE-2022-38223 2 Fedoraproject, Tats 2 Fedora, W3m 2024-11-21 N/A 7.8 HIGH
There is an out-of-bounds write in checkType located in etc.c in w3m 0.5.3. It can be triggered by sending a crafted HTML file to the w3m binary. It allows an attacker to cause Denial of Service or possibly have unspecified other impact.
CVE-2022-37864 1 Siemens 1 Solid Edge 2024-11-21 N/A 7.8 HIGH
A vulnerability has been identified in Solid Edge (All Versions < SE2022MP9). The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)
CVE-2022-37824 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGusetBasic.
CVE-2022-37823 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the list parameter in the function formSetVirtualSer.
CVE-2022-37822 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the function fromSetRouteStatic.
CVE-2022-37821 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the ProvinceCode parameter in the function formSetProvince.
CVE-2022-37820 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the ddnsEn parameter in the function formSetSysToolDDNS.
CVE-2022-37819 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the timezone parameter in the function fromSetSysTime.
CVE-2022-37818 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand.
CVE-2022-37817 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-11-21 N/A 7.8 HIGH
Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the function fromSetIpMacBind.
CVE-2022-37816 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind.
CVE-2022-37815 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the PPPOEPassword parameter in the function formQuickIndex.
CVE-2022-37814 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain multiple stack overflows via the deviceMac and the device_id parameters in the function addWifiMacFilter.
CVE-2022-37813 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetSysTime.
CVE-2022-37812 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the firewallEn parameter in the function formSetFirewallCfg.
CVE-2022-37811 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the startIp parameter in the function formSetPPTPServer.
CVE-2022-37809 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan.
CVE-2022-37808 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB.
CVE-2022-37807 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState.