Total
29514 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-8558 | 1 Kubernetes | 1 Kubernetes | 2024-11-21 | 5.8 MEDIUM | 5.4 MEDIUM |
The Kubelet and kube-proxy components in versions 1.1.0-1.16.10, 1.17.0-1.17.6, and 1.18.0-1.18.3 were found to contain a security issue which allows adjacent hosts to reach TCP and UDP services bound to 127.0.0.1 running on the node or in the node's network namespace. Such a service is generally thought to be reachable only by other processes on the same host, but due to this defeect, could be reachable by other hosts on the same LAN as the node, or by containers running on the same node as the service. | |||||
CVE-2020-8489 | 1 Abb | 1 800xa Information Management | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable. | |||||
CVE-2020-8488 | 1 Abb | 1 800xa Batch Management | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities. | |||||
CVE-2020-8487 | 1 Abb | 1 800xa Base System | 2024-11-21 | 4.6 MEDIUM | 6.6 MEDIUM |
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||||
CVE-2020-8486 | 1 Abb | 1 800xa Rnrp | 2024-11-21 | 4.6 MEDIUM | 6.6 MEDIUM |
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||||
CVE-2020-8485 | 1 Abb | 1 800xa | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | |||||
CVE-2020-8484 | 1 Abb | 1 800xa | 2024-11-21 | 4.6 MEDIUM | 7.8 HIGH |
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | |||||
CVE-2020-8300 | 1 Citrix | 16 Application Delivery Controller, Application Delivery Controller Firmware, Gateway and 13 more | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
Citrix ADC and Citrix/NetScaler Gateway before 13.0-82.41, 12.1-62.23, 11.1-65.20 and Citrix ADC 12.1-FIPS before 12.1-55.238 suffer from improper access control allowing SAML authentication hijack through a phishing attack to steal a valid user session. Note that Citrix ADC or Citrix Gateway must be configured as a SAML SP or a SAML IdP for this to be possible. | |||||
CVE-2020-8107 | 1 Bitdefender | 3 Antivirus Plus, Internet Security, Total Security | 2024-11-21 | 4.4 MEDIUM | 8.2 HIGH |
A Process Control vulnerability in ProductAgentUI.exe as used in Bitdefender Antivirus Plus allows an attacker to tamper with product settings via a specially crafted DLL file. This issue affects: Bitdefender Antivirus Plus versions prior to 24.0.26.136. Bitdefender Internet Security versions prior to 24.0.26.136. Bitdefender Total Security versions prior to 24.0.26.136. | |||||
CVE-2020-8010 | 1 Broadcom | 1 Unified Infrastructure Management | 2024-11-21 | 10.0 HIGH | 9.8 CRITICAL |
CA Unified Infrastructure Management (Nimsoft/UIM) 20.1, 20.3.x, and 9.20 and below contains an improper ACL handling vulnerability in the robot (controller) component. A remote attacker can execute commands, read from, or write to the target system. | |||||
CVE-2020-7948 | 1 Auth0 | 1 Login By Auth0 | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
An issue was discovered in the Login by Auth0 plugin before 4.0.0 for WordPress. A user can perform an insecure direct object reference. | |||||
CVE-2020-7929 | 1 Mongodb | 1 Mongodb | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
A user authorized to perform database queries may trigger denial of service by issuing specially crafted query contain a type of regex. This issue affects MongoDB Server v3.6 versions prior to 3.6.21 and MongoDB Server v4.0 versions prior to 4.0.20. | |||||
CVE-2020-7928 | 1 Mongodb | 1 Mongodb | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
A user authorized to perform database queries may trigger a read overrun and access arbitrary memory by issuing specially crafted queries. This issue affects MongoDB Server v4.4 versions prior to 4.4.1; MongoDB Server v4.2 versions prior to 4.2.9; MongoDB Server v4.0 versions prior to 4.0.20 and MongoDB Server v3.6 versions prior to 3.6.20. | |||||
CVE-2020-7868 | 2 Helpu, Microsoft | 2 Helpu, Windows | 2024-11-21 | 10.0 HIGH | 9.6 CRITICAL |
A remote code execution vulnerability exists in helpUS(remote administration tool) due to improper validation of parameter of ShellExecutionExA function used for login. | |||||
CVE-2020-7793 | 2 Siemens, Ua-parser-js Project | 2 Sinec Ins, Ua-parser-js | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexes (see linked commit for more info). | |||||
CVE-2020-7663 | 3 Canonical, Debian, Websocket-extensions Project | 3 Ubuntu Linux, Debian Linux, Websocket-extensions | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
websocket-extensions ruby module prior to 0.1.5 allows Denial of Service (DoS) via Regex Backtracking. The extension parser may take quadratic time when parsing a header containing an unclosed string parameter value whose content is a repeating two-byte sequence of a backslash and some other character. This could be abused by an attacker to conduct Regex Denial Of Service (ReDoS) on a single-threaded server by providing a malicious payload with the Sec-WebSocket-Extensions header. | |||||
CVE-2020-7662 | 1 Websocket-extensions Project | 1 Websocket-extensions | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
websocket-extensions npm module prior to 0.1.4 allows Denial of Service (DoS) via Regex Backtracking. The extension parser may take quadratic time when parsing a header containing an unclosed string parameter value whose content is a repeating two-byte sequence of a backslash and some other character. This could be abused by an attacker to conduct Regex Denial Of Service (ReDoS) on a single-threaded server by providing a malicious payload with the Sec-WebSocket-Extensions header. | |||||
CVE-2020-7622 | 1 Jooby | 1 Jooby | 2024-11-21 | 7.5 HIGH | 6.5 MEDIUM |
This affects the package io.jooby:jooby-netty before 1.6.9, from 2.0.0 and before 2.2.1. The DefaultHttpHeaders is set to false which means it does not validates that the header isn't being abused for HTTP Response Splitting. | |||||
CVE-2020-7573 | 1 Schneider-electric | 1 Webreports | 2024-11-21 | 6.4 MEDIUM | 6.5 MEDIUM |
A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control. | |||||
CVE-2020-7547 | 1 Schneider-electric | 5 Ecostruxure Energy Expert, Ecostruxure Power Monitoring Expert, Power Manager and 2 more | 2024-11-21 | 6.5 MEDIUM | 8.8 HIGH |
A CWE-284: Improper Access Control vulnerability exists in EcoStruxureª and SmartStruxureª Power Monitoring and SCADA Software (see security notification for version information) that could allow a user the ability to perform actions via the web interface at a higher privilege level. |