Vulnerabilities (CVE)

Filtered by NVD-CWE-noinfo
Total 31801 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-11542 1 Ribboncommunications 6 Sbc Swe Lite, Sbc Swe Lite Firmware, Sonus Sbc 1000 and 3 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A Remote Command Execution (RCE) vulnerability in the Sonus SBC 1000 / SBC 2000 / SBC SWe Lite web interface allows for the execution of arbitrary commands via an unspecified vector. It affects the 1000 and 2000 devices 6.0.x up to Build 446, 6.1.x up to Build 492, and 7.0.x up to Build 485. It affects the SWe Lite devices 6.1.x up to Build 111 and 7.0.x up to Build 140.
CVE-2018-11492 1 Asus 2 Hg100, Hg100 Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
ASUS HG100 devices allow denial of service via an IPv4 packet flood.
CVE-2018-11466 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known
CVE-2018-11464 1 Siemens 4 Sinumerik 828d, Sinumerik 828d Firmware, Sinumerik 840d Sl and 1 more 2024-11-21 4.3 MEDIUM 3.7 LOW
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11462 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). By sending a specially crafted authentication request to the affected systems a remote attacker could escalate his privileges to an elevated user account but not to root. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11461 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 4.6 MEDIUM 6.6 MEDIUM
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with user privileges could use the service command application for privilege escalation to an elevated user but not root. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11460 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11459 1 Siemens 10 Sinumerik 808d V4.7, Sinumerik 808d V4.7 Firmware, Sinumerik 808d V4.8 and 7 more 2024-11-21 7.2 HIGH 7.8 HIGH
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could modify a user-writeable configuration file so that after reboot or manual initiation the system reloads the modified configuration file and attacker-controlled code is executed with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11458 1 Siemens 6 Sinumerik 828d V4.7, Sinumerik 828d V4.7 Firmware, Sinumerik 840d Sl V4.7 and 3 more 2024-11-21 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11457 1 Siemens 6 Sinumerik 828d V4.7, Sinumerik 828d V4.7 Firmware, Sinumerik 840d Sl V4.7 and 3 more 2024-11-21 9.3 HIGH 8.1 HIGH
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated web server on port 4842/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 4842/tcp. Please note that this vulnerability is only exploitable if port 4842/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices on port 4842/tcp. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the web server. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11456 1 Siemens 1 Automation License Manager 2024-11-21 5.0 MEDIUM 5.8 MEDIUM
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
CVE-2018-11449 1 Siemens 2 Scalance M875, Scalance M875 Firmware 2024-11-21 2.1 LOW 7.8 HIGH
A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-11401 1 Simplisafe 2 U9k-bs1000, U9k-bs1000 Firmware 2024-11-21 4.9 MEDIUM 4.6 MEDIUM
In SimpliSafe Original, RF Interference (e.g., an extremely strong 433.92 MHz signal) by a physically proximate attacker does not cause a notification.
CVE-2018-11400 1 Simplisafe 2 U9k-bs1000, U9k-bs1000 Firmware 2024-11-21 4.9 MEDIUM 4.6 MEDIUM
In SimpliSafe Original, the Base Station fails to detect tamper attempts: it does not send a notification if a physically proximate attacker removes the battery and external power.
CVE-2018-11396 1 Gnome 1 Epiphany 2024-11-21 5.0 MEDIUM 7.5 HIGH
ephy-session.c in libephymain.so in GNOME Web (aka Epiphany) through 3.28.2.1 allows remote attackers to cause a denial of service (application crash) via JavaScript code that triggers access to a NULL URL, as demonstrated by a crafted window.open call.
CVE-2018-11329 1 Ethercartel 1 Ether Cartel 2024-11-21 5.0 MEDIUM 7.5 HIGH
The DrugDealer function of a smart contract implementation for Ether Cartel, an Ethereum game, allows attackers to take over the contract's ownership, aka ceoAnyone. After that, all the digital assets (including Ether balance and tokens) might be manipulated by the attackers, as exploited in the wild in May 2018.
CVE-2018-11284 1 Qualcomm 24 Mdm9206, Mdm9206 Firmware, Mdm9607 and 21 more 2024-11-21 8.5 HIGH 9.3 CRITICAL
Spoofed SMS can be used to send a large number of messages to the device which will in turn initiate a flood of registration updates with the server in snapdragon mobile and snapdragon wear in versions MDM9206, MDM9607, MDM9650, SD 210/SD 212/SD 205, SD 625, SD 636, SDA660, SDM630, SDM660, SDX20
CVE-2018-11257 1 Qualcomm 10 Sd 205, Sd 205 Firmware, Sd 210 and 7 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
Permissions, Privileges, and Access Controls in TA in Snapdragon Mobile has an options that allows RPMB erase for secure devices in versions SD 210/SD 212/SD 205, SD 845, SD 850.
CVE-2018-11244 1 Dopewp 1 Bbe Theme 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
The BBE theme before 1.53 for WordPress allows a direct launch of an HTML editor.
CVE-2018-11241 1 Softcase 2 T-router, T-router Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on SoftCase T-Router build 20112017 devices. A remote attacker can read and write to arbitrary files on the system as root, as demonstrated by code execution after writing to a crontab file. This is fixed in production builds as of Spring 2018.