CVE-2017-14473 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Reads the encoded ladder logic from its data file and print it out in HEX.
CVE-2017-14472 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: Any Description: Requests a specific set of bytes from an undocumented data file and returns the ASCII version of the master password.
CVE-2017-14471 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Codes: 0023, 002e, and 0037 Fault Type: Recoverable Description: The STI, EII, and HSC function files contain bits signifying whether or not a fault has occurred. Additionally there is a bit signaling the module to auto start. When these bits are set for any of the three modules and the device is moved into a run state, a fault is triggered.
CVE-2017-14470 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.
CVE-2017-14469 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 10.0 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0028 Fault Type: Non-User Description: Values 0x01 and 0x02 are invalid values for the user fault routine. By writing directly to the file it is possible to set these values. When this is done and the device is moved into a run state, a fault is triggered. NOTE: This is not possible through RSLogix.
CVE-2017-14468 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: This ability is leveraged in a larger exploit to flash custom firmware.
CVE-2017-14467 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Live rung edits are able to be made by an unauthenticated user allowing for addition, deletion, or modification of existing ladder logic. Additionally, faults and cpu state modification can be triggered if specific ladder logic is used.
CVE-2017-14466 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Description: The filetype 0x03 allows users write access, allowing the ability to overwrite the Master Password value stored in the file.
CVE-2017-14465 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE Description: Any input or output can be forced, causing unpredictable activity from the PLC.
CVE-2017-14464 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability.Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0001 Fault Type: Non-User Description: A fault state can be triggered by setting the NVRAM/memory module user program mismatch bit (S2:9) when a memory module is NOT installed.
CVE-2017-14463 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG Associated Fault Code: 0012 Fault Type: Non-User Description: A fault state can be triggered by overwriting the ladder logic data file (type 0x22 number 0x02) with null values.
CVE-2017-14462 1 Rockwellautomation 2 Micrologix 1400, Micrologix 1400 B Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG (also RUN for some) Description: Allows an attacker to enable SNMP, Modbus, DNP, and any other features in the channel configuration. Also allows attackers to change network parameters, such as IP address, name server, and domain name.
CVE-2017-14460 1 Parity 1 Ethereum Client 2024-11-21 5.1 MEDIUM 7.5 HIGH
An exploitable overly permissive cross-domain (CORS) whitelist vulnerability exists in JSON-RPC of Parity Ethereum client version 1.7.8. An automatically sent JSON object to JSON-RPC endpoint can trigger this vulnerability. A victim needs to visit a malicious website to trigger this vulnerability.
CVE-2017-14191 1 Fortinet 1 Fortiweb 2024-11-21 4.3 MEDIUM 5.9 MEDIUM
An Improper Access Control vulnerability in Fortinet FortiWeb 5.6.0 up to but not including 6.1.0 under "Signed Security Mode", allows attacker to bypass the signed user cookie protection by removing the FortiWeb own protection session cookie.
CVE-2017-14097 1 Trendmicro 1 Smart Protection Server 2024-11-21 5.0 MEDIUM 9.8 CRITICAL
An improper access control vulnerability in Trend Micro Smart Protection Server (Standalone) versions 3.2 and below could allow an attacker to decrypt contents of a database with information that could be used to access a vulnerable system.
CVE-2017-13910 1 Apple 1 Mac Os X 2024-11-21 2.1 LOW 5.5 MEDIUM
An access issue was addressed with additional sandbox restrictions on applications. This issue is fixed in macOS High Sierra 10.13. An application may be able to access restricted files.
CVE-2017-13908 1 Apple 1 Mac Os X 2024-11-21 4.6 MEDIUM 7.8 HIGH
An issue in handling file permissions was addressed with improved validation. This issue is fixed in macOS High Sierra 10.13.1, Security Update 2017-001 Sierra, and Security Update 2017-004 El Capitan, macOS High Sierra 10.13. A local attacker may be able to execute non-executable text files via an SMB share.
CVE-2017-13907 1 Apple 1 Mac Os X 2024-11-21 4.6 MEDIUM 6.8 MEDIUM
A state management issue was addressed with improved state validation. This issue is fixed in macOS High Sierra 10.13.1, Security Update 2017-001 Sierra, and Security Update 2017-004 El Capitan. The screen lock may unexpectedly remain unlocked.
CVE-2017-13892 1 Apple 2 Mac Os X, Macos 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue existed in the handling of Contact sharing. This issue was addressed with improved handling of user information. This issue is fixed in macOS High Sierra 10.13.2, Security Update 2017-002 Sierra, and Security Update 2017-005 El Capitan. Sharing contact information may lead to unexpected data sharing.
CVE-2017-13886 1 Apple 1 Mac Os X 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
In macOS High Sierra before 10.13.2, an access issue existed with privileged WiFi system configuration. This issue was addressed with additional restrictions.