CVE-2024-32316 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. | |||||
CVE-2024-32318 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function. | |||||
CVE-2024-32320 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 5.9 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | |||||
CVE-2024-33215 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat. | |||||
CVE-2024-33214 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic. | |||||
CVE-2024-33212 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm. | |||||
CVE-2024-33211 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.3 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter in ip/goform/QuickIndex. | |||||
CVE-2024-33213 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic. | |||||
CVE-2024-33217 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter in ip/goform/addressNat. | |||||
CVE-2024-48826 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | |||||
CVE-2024-48825 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | |||||
CVE-2024-32301 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | |||||
CVE-2024-32281 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | |||||
CVE-2024-35580 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formSetIptv. | |||||
CVE-2024-35579 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 7.7 HIGH |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formSetIptv. | |||||
CVE-2024-35578 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 8.0 HIGH |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv. | |||||
CVE-2024-35576 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 5.2 MEDIUM |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formSetIptv. | |||||
CVE-2024-35571 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv. | |||||
CVE-2025-25675 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution. | |||||
CVE-2025-25674 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid. |