CVE-2020-27252 | 1 Medtronic | 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware | 2025-05-22 | 9.3 HIGH | 8.8 HIGH |
Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device. | |||||
CVE-2020-25187 | 1 Medtronic | 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware | 2025-05-22 | 10.0 HIGH | 8.8 HIGH |
Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device | |||||
CVE-2020-25183 | 1 Medtronic | 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware | 2025-05-22 | 5.8 MEDIUM | 8.0 HIGH |
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication. | |||||
CVE-2019-6540 | 1 Medtronic | 46 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 43 more | 2025-05-22 | 3.3 LOW | 6.5 MEDIUM |
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data. | |||||
CVE-2019-6538 | 1 Medtronic | 40 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 37 more | 2025-05-22 | 3.3 LOW | 9.3 CRITICAL |
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device. | |||||
CVE-2003-5004 | 2025-05-22 | N/A | N/A | ||
Rejected reason: ** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. Reason: This candidate was issued in error. Notes: All references and descriptions in this candidate have been removed to prevent accidental usage. | |||||
CVE-2025-25500 | 1 Cosmwasm | 1 Cosmwasm | 2025-05-22 | N/A | 7.5 HIGH |
An issue in CosmWasm prior to v2.2.0 allows attackers to bypass capability restrictions in blockchains by exploiting a lack of runtime capability validation. This allows attackers to deploy a contract without capability enforcement, and execute unauthorized actions on the blockchain. | |||||
CVE-2025-30113 | 1 Hella | 2 Dr 820, Dr 820 Firmware | 2025-05-22 | N/A | 9.8 CRITICAL |
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Hardcoded Credentials exist in the APK for Ports 9091 and 9092. The dashcam's Android application contains hardcoded credentials that allow unauthorized access to device settings through ports 9091 and 9092. These credentials, stored in cleartext, can be exploited by an attacker who gains access to the dashcam's network. | |||||
CVE-2025-30114 | 1 Hella | 2 Dr 820, Dr 820 Firmware | 2025-05-22 | N/A | 9.1 CRITICAL |
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Bypassing of Device Pairing can occur. The pairing mechanism relies solely on the connecting device's MAC address. By obtaining the MAC address through network scanning and spoofing it, an attacker can bypass the authentication process and gain full access to the dashcam's features without proper authorization. | |||||
CVE-2025-30115 | 1 Hella | 2 Dr 820, Dr 820 Firmware | 2025-05-22 | N/A | 9.8 CRITICAL |
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Default Credentials Cannot Be Changed. It uses a fixed default SSID and password ("qwertyuiop"), which cannot be modified by users. The SSID is continuously broadcast, allowing unauthorized access to the device network. | |||||
CVE-2025-30116 | 1 Hella | 2 Dr 820, Dr 820 Firmware | 2025-05-22 | N/A | 7.5 HIGH |
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Remotely Dumping of Video Footage and the Live Video Stream can occur. It allows remote attackers to access and download recorded video footage from the SD card via port 9091. Additionally, attackers can connect to port 9092 to stream the live video feed by bypassing the challenge-response authentication mechanism. This exposes sensitive location and personal data. | |||||
CVE-2025-30117 | 1 Hella | 2 Dr 820, Dr 820 Firmware | 2025-05-22 | N/A | 7.3 HIGH |
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Managing Settings and Obtaining Sensitive Data and Sabotaging the Car Battery can be performed by unauthorized parties. After bypassing the device pairing, an attacker can obtain sensitive user and vehicle information through the settings interface. Remote attackers can modify power management settings, disable recording, delete stored footage, and turn off battery protection, leading to potential denial-of-service conditions and vehicle battery drainage. | |||||
CVE-2023-6270 | 3 Debian, Fedoraproject, Linux | 3 Debian Linux, Fedora, Linux Kernel | 2025-05-22 | N/A | 7.0 HIGH |
A flaw was found in the ATA over Ethernet (AoE) driver in the Linux kernel. The aoecmd_cfg_pkts() function improperly updates the refcnt on `struct net_device`, and a use-after-free can be triggered by racing between the free on the struct and the access through the `skbtxq` global queue. This could lead to a denial of service condition or potential code execution. | |||||
CVE-2025-45752 | 2025-05-22 | N/A | 7.2 HIGH | ||
A vulnerability in SeedDMS 6.0.32 allows an attacker with admin privileges to execute arbitrary PHP code by exploiting the zip import functionality in the Extension Manager. | |||||
CVE-2025-44083 | 2025-05-22 | N/A | 9.8 CRITICAL | ||
An issue in D-Link DI-8100 16.07.26A1 allows a remote attacker to bypass administrator login authentication | |||||
CVE-2025-27558 | 2025-05-22 | N/A | 9.1 CRITICAL | ||
IEEE P802.11-REVme D1.1 through D7.0 allows FragAttacks against mesh networks. In mesh networks using Wi-Fi Protected Access (WPA, WPA2, or WPA3) or Wired Equivalent Privacy (WEP), an adversary can exploit this vulnerability to inject arbitrary frames towards devices that support receiving non-SSP A-MSDU frames. NOTE: this issue exists because of an incorrect fix for CVE-2020-24588. P802.11-REVme, as of early 2025, is a planned release of the 802.11 standard. | |||||
CVE-2024-57529 | 2025-05-22 | N/A | 6.1 MEDIUM | ||
Cross Site Scripting vulnerability in Jeppesen JetPlanner Pro v.1.6.2.20 allows a remote attacker to execute arbitrary code. | |||||
CVE-2024-23687 | 1 Openlibraryfoundation | 1 Mod-data-export-spring | 2025-05-22 | N/A | 9.1 CRITICAL |
Hard-coded credentials in FOLIO mod-data-export-spring versions before 1.5.4 and from 2.0.0 to 2.0.2 allows unauthenticated users to access critical APIs, modify user data, modify configurations including single-sign-on, and manipulate fees/fines. | |||||
CVE-2023-50777 | 1 Jenkins | 1 Paaslane Estimate | 2025-05-22 | N/A | 4.3 MEDIUM |
Jenkins PaaSLane Estimate Plugin 1.0.4 and earlier does not mask PaaSLane authentication tokens displayed on the job configuration form, increasing the potential for attackers to observe and capture them. | |||||
CVE-2023-50768 | 1 Jenkins | 1 Nexus Platform | 2025-05-22 | N/A | 8.8 HIGH |
A cross-site request forgery (CSRF) vulnerability in Jenkins Nexus Platform Plugin 3.18.0-03 and earlier allows attackers to connect to an attacker-specified HTTP server using attacker-specified credentials IDs obtained through another method, capturing credentials stored in Jenkins. |