CVE-2025-6824 | 1 Totolink | 2 X15, X15 Firmware | 2025-07-01 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in TOTOLINK X15 up to 1.0.0-B20230714.1105. Affected is an unknown function of the file /boafrm/formParentControl of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-6846 | 1 Fabianros | 1 Simple Forum | 2025-07-01 | 7.5 HIGH | 7.3 HIGH |
A vulnerability classified as critical has been found in code-projects Simple Forum 1.0. This affects an unknown part of the file /forum_viewfile.php. The manipulation of the argument Name leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2025-6845 | 1 Fabianros | 1 Simple Forum | 2025-07-01 | 7.5 HIGH | 7.3 HIGH |
A vulnerability was found in code-projects Simple Forum 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /register1.php. The manipulation of the argument User leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-33542 | 1 Crelly Slider Project | 1 Crelly Slider | 2025-07-01 | N/A | 4.3 MEDIUM |
Authorization Bypass Through User-Controlled Key vulnerability in Fabio Rinaldi Crelly Slider.This issue affects Crelly Slider: from n/a through 1.4.5. | |||||
CVE-2012-6442 | 1 Rockwellautomation | 22 1100, 1400, 1756-enbt and 19 more | 2025-06-30 | 7.8 HIGH | N/A |
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6441 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 5.0 MEDIUM | N/A |
An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP. Successful exploitation of this vulnerability could cause loss of confidentiality. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6440 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 9.3 HIGH | N/A |
The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6439 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 8.5 HIGH | N/A |
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that changes the product’s configuration and network parameters, a DoS condition can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6438 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 7.8 HIGH | N/A |
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6437 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 10.0 HIGH | N/A |
The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6436 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 7.8 HIGH | N/A |
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the CPU to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2012-6435 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2025-06-30 | 7.8 HIGH | N/A |
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
CVE-2022-36350 | 1 Pukiwiki | 1 Pukiwiki | 2025-06-30 | N/A | 5.4 MEDIUM |
Stored cross-site scripting vulnerability in PukiWiki versions 1.3.1 to 1.5.3 allows a remote attacker to inject an arbitrary script via unspecified vectors. | |||||
CVE-2020-35509 | 1 Redhat | 1 Keycloak | 2025-06-30 | N/A | 5.4 MEDIUM |
A flaw was found in keycloak affecting versions 11.0.3 and 12.0.0. An expired certificate would be accepted by the direct-grant authenticator because of missing time stamp validations. The highest threat from this vulnerability is to data confidentiality and integrity. | |||||
CVE-2025-6494 | 2025-06-30 | 1.7 LOW | 3.3 LOW | ||
A vulnerability was found in sparklemotion nokogiri c29c920907366cb74af13b4dc2230e9c9e23b833. It has been classified as problematic. This affects the function hashmap_get_with_hash of the file gumbo-parser/src/hashmap.c. The manipulation leads to heap-based buffer overflow. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The patch is named ada4708e5a67114402cd3feb70a4e1d1d7cf773a. It is recommended to apply a patch to fix this issue. The project maintainer explains that the affected code was merged into the main branch but the commit never appeared in an official release. | |||||
CVE-2025-6490 | 2025-06-30 | 1.7 LOW | 3.3 LOW | ||
A vulnerability was found in sparklemotion nokogiri c29c920907366cb74af13b4dc2230e9c9e23b833 and classified as problematic. This issue affects the function hashmap_set_with_hash of the file gumbo-parser/src/hashmap.c. The manipulation leads to heap-based buffer overflow. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier of the patch is ada4708e5a67114402cd3feb70a4e1d1d7cf773a. It is recommended to apply a patch to fix this issue. The project maintainer explains that the affected code was merged into the main branch but the commit never appeared in an official release. | |||||
CVE-2024-53621 | 2025-06-30 | N/A | 7.5 HIGH | ||
A buffer overflow in the formSetCfm() function of Tenda AC1206 1200M 11ac US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 allows attackers to cause a Denial of Service (DoS) via a crafted POST request. | |||||
CVE-2023-47310 | 2025-06-30 | N/A | 6.5 MEDIUM | ||
A misconfiguration in the default settings of MikroTik RouterOS 7 and fixed in v7.14 allows incoming IPv6 UDP traceroute packets. | |||||
CVE-2023-28909 | 2025-06-30 | N/A | 8.0 HIGH | ||
A specific flaw exists within the Bluetooth stack of the MIB3 unit. The issue results from the lack of proper validation of user-supplied data, which can result in an integer overflow when receiving fragmented HCI packets on a channel. An attacker can leverage this vulnerability to bypass the MTU check on a channel with enabled fragmentation. Consequently, this can lead to a buffer overflow in upper layer profiles, which can be used to obtain remote code execution. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. | |||||
CVE-2023-28908 | 2025-06-30 | N/A | 5.4 MEDIUM | ||
A specific flaw exists within the Bluetooth stack of the MIB3 infotainment. The issue results from the lack of proper validation of user-supplied data, which can result in an integer overflow when receiving non-fragmented HCI packets on a channel. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. |