Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1905 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-41837 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2024-11-21 7.2 HIGH 8.2 HIGH
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
CVE-2021-41769 1 Siemens 62 6md85, 6md85 Firmware, 6md86 and 59 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.
CVE-2021-41547 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 6.5 MEDIUM 7.2 HIGH
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.11), Teamcenter Active Workspace V5.0 (All versions < V5.0.10), Teamcenter Active Workspace V5.1 (All versions < V5.1.6), Teamcenter Active Workspace V5.2 (All versions < V5.2.3). The application contains an unsafe unzipping pattern that could lead to a zip path traversal attack. This could allow and attacker to execute a remote shell with admin rights.
CVE-2021-41546 1 Siemens 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more 2024-11-21 7.8 HIGH 7.5 HIGH
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service.
CVE-2021-41545 1 Siemens 8 Desigo Dxr2, Desigo Dxr2 Firmware, Desigo Pxc3 and 5 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state.
CVE-2021-41544 1 Siemens 1 Software Center 2024-11-21 N/A 7.8 HIGH
A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path.
CVE-2021-41543 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The handling of log files in the web application of affected devices contains an information disclosure vulnerability which could allow logged in users to access sensitive files.
CVE-2021-41542 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The User Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
CVE-2021-41541 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The Group Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.
CVE-2021-41540 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).
CVE-2021-41539 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).
CVE-2021-41538 1 Siemens 13 Nx 1957, Nx 1957 Firmware, Nx 1961 and 10 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files. An attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).
CVE-2021-41537 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).
CVE-2021-41536 1 Siemens 1 Solid Edge 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).
CVE-2021-41535 1 Siemens 13 Nx 1957, Nx 1957 Firmware, Nx 1961 and 10 more 2024-11-21 6.8 MEDIUM 7.8 HIGH
A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).
CVE-2021-41534 1 Siemens 5 Nx 1984, Nx 1984 Firmware, Nx 1988 and 2 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703).
CVE-2021-41533 1 Siemens 5 Nx 1984, Nx 1984 Firmware, Nx 1988 and 2 more 2024-11-21 4.3 MEDIUM 3.3 LOW
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565).
CVE-2021-41057 3 Microsoft, Siemens, Wibu 11 Windows, Pss Cape, Pss E and 8 more 2024-11-21 3.6 LOW 7.1 HIGH
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
CVE-2021-40368 1 Siemens 8 Simatic S7-400 Pn\/dp V7, Simatic S7-400 Pn\/dp V7 Firmware, Simatic S7-400h V6 and 5 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations.
CVE-2021-40366 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 5.8 MEDIUM 7.4 HIGH
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.