Filtered by vendor Siemens
Subscribe
Total
1893 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-7974 | 4 Debian, Netapp, Ntp and 1 more | 8 Debian Linux, Clustered Data Ontap, Oncommand Balance and 5 more | 2025-04-12 | 4.0 MEDIUM | 7.7 HIGH |
NTP 4.x before 4.2.8p6 and 4.3.x before 4.3.90 do not verify peer associations of symmetric keys when authenticating packets, which might allow remote attackers to conduct impersonation attacks via an arbitrary trusted key, aka a "skeleton key." | |||||
CVE-2015-8214 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | 9.7 HIGH | N/A |
A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs. | |||||
CVE-2015-3610 | 1 Siemens | 1 Homecontrol For Room Automation | 2025-04-12 | 5.4 MEDIUM | N/A |
The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate. | |||||
CVE-2016-8672 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server delivers cookies without the "secure" flag. Modern browsers interpreting the flag would mitigate potential data leakage in case of clear text transmission. | |||||
CVE-2014-2731 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 9.3 HIGH | N/A |
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80. | |||||
CVE-2016-9154 | 1 Siemens | 12 Desigo Web Module Pxa30-w0, Desigo Web Module Pxa30-w0 Firmware, Desigo Web Module Pxa30-w1 and 9 more | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
Siemens Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 for Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D (All firmware versions < V6.00.046) and Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 for Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U (All firmware versions < V6.00.046) use a pseudo random number generator with insufficient entropy to generate certificates for HTTPS, potentially allowing remote attackers to reconstruct the corresponding private key. | |||||
CVE-2015-5374 | 1 Siemens | 3 Siprotec 4, Siprotec Compact, Siprotec Firmware | 2025-04-12 | 7.8 HIGH | N/A |
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. | |||||
CVE-2014-8552 | 1 Siemens | 4 Simatic Pcs7, Simatic Pcs 7, Simatic Tiaportal and 1 more | 2025-04-12 | 5.0 MEDIUM | N/A |
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. | |||||
CVE-2014-5233 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2025-04-12 | 1.9 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. | |||||
CVE-2014-8478 | 1 Siemens | 9 Scalance X-300, Scalance X-300 Series Firmware, Scalance X-300eec and 6 more | 2025-04-12 | 7.8 HIGH | N/A |
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests. | |||||
CVE-2015-2822 | 1 Siemens | 1 Wincc | 2025-04-12 | 4.3 MEDIUM | N/A |
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. | |||||
CVE-2016-4955 | 6 Novell, Ntp, Opensuse and 3 more | 11 Suse Manager, Ntp, Leap and 8 more | 2025-04-12 | 4.3 MEDIUM | 5.9 MEDIUM |
ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service (peer-variable clearing and association outage) by sending (1) a spoofed crypto-NAK packet or (2) a packet with an incorrect MAC value at a certain time. | |||||
CVE-2014-2257 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets. | |||||
CVE-2016-7959 | 1 Siemens | 1 Simatic Step 7 | 2025-04-12 | 1.9 LOW | 4.7 MEDIUM |
Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack. | |||||
CVE-2015-4174 | 1 Siemens | 1 Climatix Bacnet\/ip | 2025-04-12 | 4.3 MEDIUM | N/A |
Cross-site scripting (XSS) vulnerability in the integrated web server on the Siemens Climatix BACnet/IP communication module with firmware before 10.34 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2016-8563 | 1 Siemens | 1 Automation License Manager | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to cause a denial of service (ALM service outage) via crafted packets to TCP port 4410. | |||||
CVE-2014-2732 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 5.0 MEDIUM | N/A |
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80. | |||||
CVE-2014-5231 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2025-04-12 | 2.1 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. | |||||
CVE-2016-5849 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 1.9 LOW | 2.5 LOW |
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | |||||
CVE-2016-4954 | 5 Ntp, Opensuse, Oracle and 2 more | 15 Ntp, Leap, Opensuse and 12 more | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
The process_packet function in ntp_proto.c in ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (peer-variable modification) by sending spoofed packets from many source IP addresses in a certain scenario, as demonstrated by triggering an incorrect leap indication. |