Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1893 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2014-4683 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-12 4.9 MEDIUM N/A
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
CVE-2015-1594 1 Siemens 5 Simatic Cfc, Simatic Prosave, Simatic Step 7 and 2 more 2025-04-12 6.9 MEDIUM N/A
Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows local users to gain privileges via a Trojan horse application file.
CVE-2014-0224 9 Fedoraproject, Filezilla-project, Mariadb and 6 more 20 Fedora, Filezilla Server, Mariadb and 17 more 2025-04-12 5.8 MEDIUM 7.4 HIGH
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
CVE-2015-1595 1 Siemens 1 Spcanywhere 2025-04-12 4.3 MEDIUM N/A
The Siemens SPCanywhere application for Android and iOS does not use encryption during lookups of system ID to IP address mappings, which allows man-in-the-middle attackers to discover alarm IP addresses and spoof servers by intercepting the client-server data stream.
CVE-2014-2253 1 Siemens 1 Simatic S7-1500 Cpu Firmware 2025-04-12 6.1 MEDIUM N/A
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets.
CVE-2016-9159 1 Siemens 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more 2025-04-12 4.3 MEDIUM 5.9 MEDIUM
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
CVE-2015-1357 1 Siemens 5 Ruggedcom Firmware, Ruggedcom Win5100, Ruggedcom Win5200 and 2 more 2025-04-12 5.0 MEDIUM N/A
Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs.
CVE-2014-5232 2 Apple, Siemens 2 Iphone Os, Simatic Wincc Sm\@rtclient 2025-04-12 1.9 LOW N/A
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state.
CVE-2016-5848 1 Siemens 1 Sicam Pas\/pqs 2025-04-12 1.7 LOW 6.7 MEDIUM
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges.
CVE-2014-4685 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-12 4.6 MEDIUM N/A
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
CVE-2014-2255 1 Siemens 1 Simatic S7-1500 Cpu Firmware 2025-04-12 7.8 HIGH N/A
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.
CVE-2016-7960 1 Siemens 1 Simatic Step 7 2025-04-12 1.9 LOW 2.5 LOW
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
CVE-2016-8673 1 Siemens 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more 2025-04-12 6.8 MEDIUM 8.8 HIGH
A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS variants) (All versions). The integrated web server at port 80/TCP or port 443/TCP of the affected devices could allow remote attackers to perform actions with the permissions of an authenticated user, provided the targeted user has an active session and is induced to trigger the malicious request.
CVE-2014-8551 1 Siemens 4 Simatic Pcs7, Simatic Pcs 7, Simatic Tiaportal and 1 more 2025-04-12 10.0 HIGH N/A
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
CVE-2014-2259 1 Siemens 1 Simatic S7-1500 Cpu Firmware 2025-04-12 7.8 HIGH N/A
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.
CVE-2016-1488 1 Siemens 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more 2025-04-12 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2016-6204 1 Siemens 1 Sinema Remote Connect Server 2025-04-12 4.3 MEDIUM 6.1 MEDIUM
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2016-9156 1 Siemens 1 Sicam Pas\/pqs 2025-04-12 7.5 HIGH 7.3 HIGH
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP.
CVE-2014-4686 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-12 6.8 MEDIUM N/A
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030.
CVE-2014-5074 1 Siemens 8 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1513-1 Pn Cpu and 5 more 2025-04-12 7.1 HIGH N/A
Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.