Total
309453 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-12726 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 7.5 HIGH | 7.3 HIGH |
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. | |||||
CVE-2017-12725 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 6.8 MEDIUM | 5.6 MEDIUM |
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. | |||||
CVE-2017-12724 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 6.8 MEDIUM | 8.1 HIGH |
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. | |||||
CVE-2017-12723 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 4.3 MEDIUM | 3.7 LOW |
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications. | |||||
CVE-2017-12722 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. | |||||
CVE-2017-12721 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. | |||||
CVE-2017-12720 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 6.8 MEDIUM | 8.1 HIGH |
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. | |||||
CVE-2017-12718 | 1 Smiths-medical | 1 Medfusion 4000 Wireless Syringe Infusion Pump | 2024-11-21 | 6.8 MEDIUM | 8.1 HIGH |
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. | |||||
CVE-2017-12716 | 1 Abbott | 8 Accent, Accent Firmware, Accent Mri and 5 more | 2024-11-21 | 3.3 LOW | 6.5 MEDIUM |
Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | |||||
CVE-2017-12714 | 1 Abbott | 14 Accent, Accent Firmware, Accent Mri and 11 more | 2024-11-21 | 6.1 MEDIUM | 6.5 MEDIUM |
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | |||||
CVE-2017-12712 | 1 Abbott | 14 Accent, Accent Firmware, Accent Mri and 11 more | 2024-11-21 | 8.3 HIGH | 8.8 HIGH |
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities. | |||||
CVE-2017-12701 | 1 Cpap | 2 Luna Cpap Machine, Luna Cpap Machine Firmware | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
BMC Medical Luna CPAP Machines released prior to July 1, 2017, contain an improper input validation vulnerability which may allow an authenticated attacker to crash the CPAP's Wi-Fi module resulting in a denial-of-service condition. | |||||
CVE-2017-12697 | 1 Gm | 1 Shanghai Onstar | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
A Man-in-the-Middle issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow an attacker to intercept sensitive information when the client connects to the server. | |||||
CVE-2017-12695 | 1 Gm | 1 Shanghai Onstar | 2024-11-21 | 4.0 MEDIUM | 8.8 HIGH |
An Improper Authentication issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow an attacker to subvert security mechanisms and reset a user account password. | |||||
CVE-2017-12632 | 1 Apache | 1 Nifi | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A malicious host header in an incoming HTTP request could cause NiFi to load resources from an external server. The fix to sanitize host headers and compare to a controlled whitelist was applied on the Apache NiFi 1.5.0 release. Users running a prior 1.x release should upgrade to the appropriate release. | |||||
CVE-2017-12627 | 1 Apache | 1 Xerces-c\+\+ | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
In Apache Xerces-C XML Parser library before 3.2.1, processing of external DTD paths can result in a null pointer dereference under certain conditions. | |||||
CVE-2017-12626 | 1 Apache | 1 Poi | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Apache POI in versions prior to release 3.17 are vulnerable to Denial of Service Attacks: 1) Infinite Loops while parsing crafted WMF, EMF, MSG and macros (POI bugs 61338 and 61294), and 2) Out of Memory Exceptions while parsing crafted DOC, PPT and XLS (POI bugs 52372 and 61295). | |||||
CVE-2017-12622 | 1 Apache | 1 Geode | 2024-11-21 | 5.5 MEDIUM | 7.1 HIGH |
When an Apache Geode cluster before v1.3.0 is operating in secure mode and an authenticated user connects to a Geode cluster using the gfsh tool with HTTP, the user is able to obtain status information and control cluster members even without CLUSTER:MANAGE privileges. | |||||
CVE-2017-12619 | 1 Apache | 1 Zeppelin | 2024-11-21 | 5.8 MEDIUM | 8.1 HIGH |
Apache Zeppelin prior to 0.7.3 was vulnerable to session fixation which allowed an attacker to hijack a valid user session. Issue was reported by "stone lone". | |||||
CVE-2017-12614 | 1 Apache | 1 Airflow | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
It was noticed an XSS in certain 404 pages that could be exploited to perform an XSS attack. Chrome will detect this as a reflected XSS attempt and prevent the page from loading. Firefox and other browsers don't, and are vulnerable to this attack. Mitigation: The fix for this is to upgrade to Apache Airflow 1.9.0 or above. |