Vulnerabilities (CVE)

Total 309456 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2017-12622 1 Apache 1 Geode 2024-11-21 5.5 MEDIUM 7.1 HIGH
When an Apache Geode cluster before v1.3.0 is operating in secure mode and an authenticated user connects to a Geode cluster using the gfsh tool with HTTP, the user is able to obtain status information and control cluster members even without CLUSTER:MANAGE privileges.
CVE-2017-12619 1 Apache 1 Zeppelin 2024-11-21 5.8 MEDIUM 8.1 HIGH
Apache Zeppelin prior to 0.7.3 was vulnerable to session fixation which allowed an attacker to hijack a valid user session. Issue was reported by "stone lone".
CVE-2017-12614 1 Apache 1 Airflow 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
It was noticed an XSS in certain 404 pages that could be exploited to perform an XSS attack. Chrome will detect this as a reflected XSS attempt and prevent the page from loading. Firefox and other browsers don't, and are vulnerable to this attack. Mitigation: The fix for this is to upgrade to Apache Airflow 1.9.0 or above.
CVE-2017-12610 1 Apache 1 Kafka 2024-11-21 4.9 MEDIUM 6.8 MEDIUM
In Apache Kafka 0.10.0.0 to 0.10.2.1 and 0.11.0.0 to 0.11.0.1, authenticated Kafka clients may use impersonation via a manually crafted protocol message with SASL/PLAIN or SASL/SCRAM authentication when using the built-in PLAIN or SCRAM server implementations in Apache Kafka.
CVE-2017-12590 1 Asus 2 Rt-n14uhp, Rt-n14uhp Firmware 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
ASUS RT-N14UHP devices before 3.0.0.4.380.8015 have a reflected XSS vulnerability in the "flag" parameter.
CVE-2017-12580 1 Ultraedit 1 Ultraedit 2024-11-21 6.9 MEDIUM 7.8 HIGH
An issue was discovered in IDM UltraEdit through 24.10.0.32. To exploit the vulnerability, on unpatched Windows systems, an attacker could include in the same directory as the affected executable a DLL using the name of a Windows DLL. This DLL must be preloaded by the executable (for example, "ntmarta.dll"). When the installer EXE is executed by the user, the DLL located in the EXE's current directory will be loaded instead of the Windows DLL, allowing the attacker to run arbitrary code on the affected system.
CVE-2017-12577 1 Planex 3 Cs-qr20, Cs-qr20 Firmware, Smacam Night Vision 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on the PLANEX CS-QR20 1.30. A hardcoded account / password ("admin:password") is used in the Android application that allows attackers to use a hidden API URL "/goform/SystemCommand" to execute any command with root permission.
CVE-2017-12576 1 Planex 2 Cs-qr20, Cs-qr20 Firmware 2024-11-21 9.0 HIGH 7.2 HIGH
An issue was discovered on the PLANEX CS-QR20 1.30. A hidden and undocumented management page allows an attacker to execute arbitrary code on the device when the user is authenticated. The management page was used for debugging purposes, once you login and access the page directly (/admin/system_command.asp), you can execute any command.
CVE-2017-12575 1 Aterm 2 Wg2600hp2, Wg2600hp2 Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An issue was discovered on the NEC Aterm WG2600HP2 1.0.2. The router has a set of web service APIs for access to and setup of the configuration. Some APIs don't require authentication. An attacker could exploit this vulnerability by sending a crafted HTTP request to retrieve DHCP clients, firmware version, and network status (ex.: curl -X http://[IP]/aterm_httpif.cgi/negotiate -d "REQ_ID=SUPPORT_IF_GET").
CVE-2017-12574 1 Planex 2 Cs-w50hd, Cs-w50hd Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. A hardcoded credential "supervisor:dangerous" was injected into web authentication database "/.htpasswd" during booting process, which allows attackers to gain unauthorized access and control the device completely; the account can't be modified or deleted.
CVE-2017-12573 1 Planex 2 Cs-w50hd, Cs-w50hd Firmware 2024-11-21 9.0 HIGH 8.8 HIGH
An issue was discovered on PLANEX CS-W50HD devices with firmware before 030720. The device has a command-injection vulnerability in the web management UI on NAS settings page "/cgi-bin/nasset.cgi". An attacker can send a crafted HTTP POST request to execute arbitrary code. Authentication is required before executing the attack.
CVE-2017-12561 1 Hp 1 Intelligent Management Center 2024-11-21 10.0 HIGH 9.8 CRITICAL
A remote code execution vulnerability in HPE intelligent Management Center (iMC) PLAT version Plat 7.3 E0504P4 and earlier was found.
CVE-2017-12560 1 Hp 1 Intelligent Management Center 2024-11-21 6.8 MEDIUM 6.5 MEDIUM
A Remote Denial of Service vulnerability in HPE Intelligent Management Center (iMC) PLAT version iMC Plat 7.3 E0504P2 was found.
CVE-2017-12559 1 Hp 1 Intelligent Management Center 2024-11-21 6.8 MEDIUM 6.5 MEDIUM
A Remote Denial of Service vulnerability in HPE Intelligent Management Center (iMC) PLAT version iMC Plat 7.3 E0504P2 was found.
CVE-2017-12558 1 Hp 1 Intelligent Management Center 2024-11-21 10.0 HIGH 9.8 CRITICAL
A Remote Code Execution vulnerability in HPE intelligent Management Center (iMC) PLAT version IMC Plat 7.3 E0504P2 and earlier was found.
CVE-2017-12557 1 Hp 1 Intelligent Management Center 2024-11-21 10.0 HIGH 9.8 CRITICAL
A Remote Code Execution vulnerability in HPE intelligent Management Center (iMC) PLAT version IMC Plat 7.3 E0504P2 and earlier was found.
CVE-2017-12556 1 Hp 1 Intelligent Management Center 2024-11-21 10.0 HIGH 9.8 CRITICAL
A Remote Code Execution vulnerability in HPE intelligent Management Center (iMC) PLAT version IMC Plat 7.3 E0504P2 and earlier was found.
CVE-2017-12555 1 Hp 1 Intelligent Management Center 2024-11-21 6.8 MEDIUM 6.5 MEDIUM
A remote arbitrary file download and disclosure of information vulnerability in HPE Intelligent Management Center (iMC) Service Operation Management (SOM) version IMC SOM 7.3 E0501 was found.
CVE-2017-12554 1 Hp 1 Intelligent Management Center 2024-11-21 9.0 HIGH 8.8 HIGH
A remote code execution vulnerability in HPE intelligent Management Center (iMC) PLAT iMC Plat 7.3 E0504P2 and earlier was found.
CVE-2017-12553 3 Hp, Linux, Microsoft 3 System Management Homepage, Linux Kernel, Windows 2024-11-21 5.5 MEDIUM 5.6 MEDIUM
A local authentication bypass vulnerability in HPE System Management Homepage for Windows and Linux version prior to v7.6.1 was found.